Replenishment Procedure
900NF Acid
Neutralizing Filter
The 900NF appliance requires periodic (annual) replenishment of the neutralizing media that adjusts the pH level
of the water. Use the freeboard distance as described in the following section and the diagram to determine the
amount of media needed to adjust the bed depth to maintain optimum performance of the neutralizer.
Tools and Materials Needed
The following tools and materials are needed to replenish the acid neutralizer:
Replenishment Procedure
The replenishment procedure is as follows:
Turn Off the Water
A. Turn off the water to the appliance.
B. Open a tap to depressurize the appliance.
C. Close the tap.
Siphon Off All Water
A. Use the three-quarter-inch socket to
remove the fill plug from the media tank.
B. Insert a siphon hose into the fill port and
siphon off all water down to the media level in
the tank into a five-gallon bucket.
Determine Amount of
Replenishment Media
Required
A. Use a wooden ruler to measure the freeboard distance from the top of the fill plug to the media.
B. The recommended freeboard is 6.5 inches. Add 4.5 lb of media per inch below 6.5 inches.
Example
: Measured Freeboard 8.5 in.
Min
us Factory Freeboard 6.5 in.
Equals Adjusted Freeboard 2.0 in.
Replenishment equals 4.5 lb media X 2.0 in. (adjusted freeboard) = 9 lb media
STEP 1
STEP 2
16
Media Bed
A dd 9 lb s .
R ec o m m en ded fr eeb o ard
Analog scale (do NOT use a digital scale)
Five-gallon bucket with handle
0.5-inch, four-foot long siphon hose
12-inch wooden ruler (or wooden dowel rod and a
tape measure)
Replacement media (P/N M050)
Funnel with one-inch fill tube
Three-quarter-inch socket with ratchet
*
STEP 3